Ada Reference ManualLegal Information
Contents   Index   References   Search   Previous   Next 

D.10 Synchronous Task Control

1/3
This subclause describes a language-defined private semaphore (suspension object), which can be used for two-stage suspend operations and as a simple building block for implementing higher-level queues. 

Static Semantics

2
The following language-defined package exists: 
3/2
package Ada.Synchronous_Task_Control is
  pragma Preelaborate(Synchronous_Task_Control);
4
  type Suspension_Object is limited private;
  procedure Set_True(S : in out Suspension_Object);
  procedure Set_False(S : in out Suspension_Object);
  function Current_State(S : Suspension_Object) return Boolean;
  procedure Suspend_Until_True(S : in out Suspension_Object);
private
     ... -- not specified by the language
end Ada.Synchronous_Task_Control;
5
The type Suspension_Object is a by-reference type.
5.1/3
  The following language-defined package exists: 
5.2/3
package Ada.Synchronous_Task_Control.EDF is
   procedure Suspend_Until_True_And_Set_Deadline
      (S  : in out Suspension_Object;
       TS : in     Ada.Real_Time.Time_Span);
end Ada.Synchronous_Task_Control.EDF;

Dynamic Semantics

6/2
An object of the type Suspension_Object has two visible states: True and False. Upon initialization, its value is set to False.
7/2
The operations Set_True and Set_False are atomic with respect to each other and with respect to Suspend_Until_True; they set the state to True and False respectively.
8
Current_State returns the current state of the object.
9/2
The procedure Suspend_Until_True blocks the calling task until the state of the object S is True; at that point the task becomes ready and the state of the object becomes False.
10
Program_Error is raised upon calling Suspend_Until_True if another task is already waiting on that suspension object. Suspend_Until_True is a potentially blocking operation (see 9.5.1).
10.1/3
   The procedure Suspend_Until_True_And_Set_Deadline blocks the calling task until the state of the object S is True; at that point the task becomes ready with a deadline of Ada.Real_Time.Clock + TS, and the state of the object becomes False. Program_Error is raised upon calling Suspend_Until_True_And_Set_Deadline if another task is already waiting on that suspension object. Suspend_Until_True_And_Set_Deadline is a potentially blocking operation. 

Implementation Requirements

11
The implementation is required to allow the calling of Set_False and Set_True during any protected action, even one that has its ceiling priority in the Interrupt_Priority range.
NOTES
12/3
37  More complex schemes, such as setting the deadline relative to when Set_True is called, can be programmed using a protected object. 

Contents   Index   References   Search   Previous   Next 